![FLIGHT DESIGN CTLS Series Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/flight-design/ctls-series/ctls-series_maintenance-and-inspection-procedures-manual_2305270092.webp)
Maintenance and Inspection Procedures Manual
Type:
CT
Series:
CTLS
LSA
Page: 4-55
AF 04800001
Revision No. 3
Date: 14 Sep 2008
Flap deflection can be adjusted by the flap control panel. Check flap angle of deflection after each
adjustment by means of electronic level.
1. Connect printed circuit board (PCB) connectors with corresponding headers of the flap actuator
control (Control Card MT-10) wiring harness (Fig. 9).
2. Connect auxiliary control switches SW1 and SW2 to corresponding connectors at the PCB for
programming.
3. Set the flap into required position by SW2 using a level. Set the digital screen indication
corresponding to the value at the level by SW3.
4. Press SW1 to input data into the PCB memory. If the operation has been performed correctly the
display shows the value set by SW3.
5. Move the flap by SW2 to the next required position using a level. Change the value at the screen
by SW3 according to the value at the level. Press SW1 to save settings into the memory.
6. Repeat the process for each of the flap positions.
7. If you cannot adjust (set) max angles of deflection (the rod of the flap actuator takes the end
position), this problem could be solved by adjusting the length of the rod of flap control. The
length of the rod can be adjusted only following the item 4.4.1.5.
8. After rigging all flap positions turn off the circuit breaker 25A.
9. Remove the switches SW1 and SW2.
10. Turn the circuit breaker 25A on.
11. If the instruction has been performed correctly the flaps will take their predefined positions.
Fig. 9