9 Measurement
9.1 Parameter input
FLUXUS G801
2020-06-26, UMFLUXUS_G801V1-0EN
84
Pipe wall thickness
• Enter the pipe wall thickness.
• Press ENTER.
Pipe material
The pipe material has to be selected to be able to determine the corresponding sound speed.
The sound speeds for the materials in the scroll list are stored in the transmitter.
• Select the pipe material.
• If the material is not in the scroll list, select
Other Material
.
• Press ENTER.
Sound speed of the pipe material
• Enter the sound speed of the pipe material.
• Press ENTER.
This display will only be indicated if
Other Material
is selected.
Lining
• Select
yes
if the pipe has a lining. Select
no
if it has no lining.
• Press ENTER.
Lining material
• Select the lining material.
• If the lining material is not included in the scroll list, select
Other Material
.
• Press ENTER.
This display will only be indicated if
yes
is selected in the menu item
Lining
.
Sound speed of the lining material
• Enter the sound speed of the lining material.
• Press ENTER.
This display will only be indicated if
Other Material
is selected.
Parameter\Wall Thickness
Parameter\Pipe Material
Parameter\Pipe Material\Other Material\c-Material
Notice!
There are 2 sound speeds for pipe materials: the longitudinal and the transversal one. Enter the sound speed which
is nearer to 2500 m/s.
Parameter\Lining
Parameter\Lining
Parameter\Lining\Other Material\c-Material
Notice!
There are 2 sound speeds for lining materials: the longitudinal and the transversal one. Enter the sound speed which
is nearer to 2500 m/s.