Timer in sanitary water preparation regime
Function of the timer in sanitary water preparation regime
A timer appears on the display next to the symbol of boiler in the setting
mode when the function of sanitary water preparation is enabled. Format
of the timer is
00:00 - 00:00
(24h marking time).
It appears only when the function is CHECKED.
The devices comes as factory-set at
00:00 - 00.00
which means that the
timer allows the preparation of sanitary water throughout the day. If two
times are set, for example:
22:50 - 22:50
, the preparation of sanitary
water is still possible throughout the day.
This function is introduced in order to connect the boiler to another
heating system, for example: solar or to solid fuel boiler. It is good then to
set up the preparation of sanitary water in a certain period of time when
there is no sun or when the solid fuel boiler is not charged.
The image shows an example of setting the function of the preparation of
sanitary water for a period of time from 20:00 to 04:00. There is no energy
of the sun in this period, so it is necessary to prepare sanitary water for
use in the evening or in the morning hours.
This setting also allows the preparation of sanitary water in hours of less
expensive electricity.
Setting
When the sanitary water preparation regime is enabled, a timer appears on the display. We go through the setting parameters
by pressing the OK button. Time will start to flash in the following order:
00
:00 - 00:00
– hours of switching on are set (for example 20)
20:
00
- 00:00 - minutes of switching on are set (for example 30)
20:30 -
00
:00 - hours of switching off are set (for example 04)
20:30 - 04:
00
- minutes of switching off are set (for example 30)
Means that we set the time to
20:30 - 04:30
Every setting in any regime is confirmed by pressing the SET button.