Setting the operating regime
7.5
Sanitary water preparation regime
The Compact ePlus device has the option of controlling a
three-way motor valve in order to enable the heating of
sanitary water in the boiler with a heat exchanger.
7.5.1 Setting desired regimes
In order to select the desired operating regime of the
device, press and hold the SET button for more than 3
seconds. Then an overview will appear on the display
as in Image 21.
A) Symbol of heating regime
B) Symbol of sanitary water preparation regime
C) Selection of security mode at low temperatures
D) Symbol of clock for setting time and date
Desired regime is chosen by simply selecting the
symbol and its setting (X) SWITCHED OFF (
√
)
SWITCHED ON
Symbols are changed by pressing the
▲▼buttons.
1. Setting HEATING (ON)
– SANITARY WATER (OFF) - Safety STANDARD Image 21 (Above)
2. ALL SWITCHED ON.
Regimes of heating and preparation of sanitary water are switched on
Safety: standard setting.
The boiler will operate normally when the room thermostat requires
room heating.
When the room
thermostat switches off the boiler, that is, when the
room is warmed, processor reads temperature in the boiler and if it is
lower than the set one it gives the command to the boiler to heat the
sanitary water by the three-way motor valve which is run by the
boiler.
STANDARD Safety
– which means that the device is not set to anti-
freezing mode and that there is ordinary water in the system and not
the thermofluid.
Setting HEATING (ON)
– SANITARY WATER (ON) Safety STANDARD
Image 22 (above)
NOTE: Perform setting and selecting of the regime in which the boiler will operate only when the room
thermostat does not require heating and when the basic elements of the boiler, such as pump and heaters,
are not included.