Installation of the device
4.
Installation of the device
CAUTION:
Human or material damages
caused by improper installation!
Never install the boiler without an expansion
container (AG) and a safety valve.
The boiler must not be installed in the protective
zone of the wet area and the area where a bathtub
is located.
NOTE:
Material damages from freezing!
The boiler may only be installed in rooms where
freezing cannot occur.
4.2
Distance
DANGER:
Fire hazard due to flammable
materials or liquids!
Do not dispose of flammable materials or
liquids near the boiler.
Inform the user about applicable regulations
of minimum distances from highly flammable
materials (
chapter 2.8, page 7).
4.1
Be careful about the following
before installation
NOTE:
Material damages caused by non-
compliance with further instructions!
Follow the instructions for the boiler and all
installed components.
• follow the regulations on electrical installations
and the minimum distances which are in force in
the countries concerned.
• set the boiler on the wall in such a way that there remains the
minimum free space as shown in Image no.3
Before installing, keep an eye on the following
:
• all electrical connections, protection measures and
fuses should be carried out by an authorized person,
complying with all applicable norms and regulations
as well as local regulations.
• the electrical connection must be carried out according to
connection schemes.
• after proper installation of the device, carry
out the grounding.
• switch off the electric power before opening and
all operations.
• unprofessional and unauthorized attempts of
connection can cause material damages to the device
and lead to dangerous electric shocks.
A
=
500mm
/
B
=
50mm
/
C
=
200mm
/
D
=
500mm
Image number
3
Minimum distances during installation