Setting the operating regime
THE SETTING MODE IS ENTERED BY SHORT PRESSING OF THE ‘SET’ BUTTON IN ANY REGIME:
The display shows
'G'
, the set temperature of heating starts to flash and it can be set in the range of 10 -
80˚C.
When it is set -
by pressing
'OK'
, it switches to the setting of the following parameter: the set power of heating flashes - after the setting (if
preparation of sanitary water is not activated), if the 'OK' button is pressed, the set heating temperature flashes and thus in
circle. To remember the changes that are made, that is, the new set values and to exit from the setting, the
'SET'
button must
be pressed. If the
'SET'
button is not pressed within 15 seconds from the last pressing of some of the other buttons, the
processor exits the setting mode and continues to work according to the “old” set values of power and temperature.
The setting is continued after setting the temperature and the power of the heating, if the preparation of sanitary water is
activated as well:
- now, instead of the symbol of radiator, the symbol of boiler appears (overview
'B'
). The presented current temperature is the
temperature of the boiler, and the set temperature of the boiler that can be set in the range of 10 -
70˚C starts to flash and it is
taken (increased by 15˚C max. 80˚C) as the temperature to which the boiler is heated while in the sanitary water preparation
regime. If the
‘OK’
button is pressed after setting this temperature, the set power of the boiler for the preparation of the sanitary
water begins to flash, and it should be set taking into account the volume of the boiler, the power of the heat exchanger and the
nominal power of the boiler, that is, choose the optimum power for preparation of hot water in the boiler. To remember the
changes that are made, that is, the new set values and to exit from the setting, the
'SET'
button must be pressed. If the
'SET'
button is not pressed within 15 seconds from the last pressing of some of the other buttons, the processor exits the setting mode
and continues to work according to the “old” set values of power and temperature.