Handling the heating installation
7.3
Heating regulation
Setting heating parameters
Based on the display on the screen (Image 13), there can be
read:
1 Time
2 Date
4 Current temperature of the system
5 The set temperature of the system
8 Operating pressure in the system
11 Current power
12 The set power of the boiler
15 Information on operation of the pump
- if the pump symbol is on the screen the PUMP is
SWITCHED ON AND WORKS
17 Information on the status of the room thermostat
- if the symbol is on the screen the ROOM
THERMOSTAT IS SWITCHED ON
current set
values
Image
14
Setting the operating temperature of the boiler
Setting the power of the boiler
- If a change is confirmed after the temperature is set (press OK),
the controller switches to power adjustment. If we do not want to
change the temperature, but only the power, when the value of
the set temperature begins to flash, press the OK button and
switch to the power setting of the boiler. The set value of power
of the boiler starts to flash, and it is now possible to increase or
decrease it by using the buttons
Each use of the button increases the power of the
Boiler by 1,5kW, and every use of the button
reduces
the
power of the boiler by 1,5kW. So, it is possible to set one of
the following values of power of the boiler: 1,5kW; 3kW ;
4,5kW
;6kW ; 7,5kW ; 9kW (FOR BOILER OF 9kW POWER).
The change must be confirmed by pressing the SET button.
If the change is not confirmed, after 15 seconds from pressing any
button (except SET), the controller continues to operate according
to the old value of the set power and exits the setting mode.
Image
13
Setting operating temperature of the boiler
- By pressing the SET button you enter the mode for setting
parameters. The set operating temperature of the boiler is
flashing, which can now be increased or decreased with the
buttons and Each press on the button increases or
decreases the operating temperat
ure of the boiler by one °C.
The change must be confirmed by pressing the SET button.
If
the change is not confirmed, after 15 seconds from pressing any
button (except SET), the controller continues to operate according
to the old value of the set temperature and exits the setting mode.
C
Current power Set power
Image 15 Setting the power of the boiler