13 General messages
General messages
STOP
Stop
/ Reset state, wait for next incoming command
_Eu_
Lower limit position
Eu
lower limit position locked
raising not possible (e.g., lock-door)
ZUF
@
Closing active
-Eo-
Upper limit position
Eo
upper limit position locked
closing not possible (e.g., safety edge)
@
OPE
Opening active
-E1-
middle limit position E1 (intermediate stop position)
E1
upper limit position
locked closing not possible (e.g., safety edge)
FAIL
Fault
only deadman travel is possible, automatic opening may also be possible
"CALI:
Calibration
setting the limit positions in deadman travel mode
(for absolute encoder )
Start procedure using STOP key
NA
E-stop
Travel not possible, hardware safety chain interrupted
HdSA:
E-travel
Deadman travel without regard for safety facilities, etc.
'Hd'
Manual
Deadman mode
ParA
Parametrization
SYNC:
Synchronization
(incremental encoder / limit switch
Pos.unknown)
'Au'
Automatic
indicates change from "Manual" to "Automatic" status
'Hc'
Semi automatic
indicates change from "Manual" to "Semi-automatic"
WU:
first display after switching on (Power Up and Self-test)
Status messages during calibration
E.i.E.c.:
calibration of the lower limit position requested (in deadman travel)
E.i.E.o.:
calibration of the lower limit position requested (in deadman travel)
E.i.E.1
calibration of intermediate position E1 (in deadman travel)
Status messages during synchronization:
S.y.E.c.:
Synchronization of lower limit position requested
(deadman or wait for starting condition)
S.y.E.o.
Synchronization of lower upper position requested
(deadman or wait for starting condition)
S.y.E.1
Synchronization of intermediate stop position E1 (in deadman mode)
S.y.op:
Automatic opening up to mechanical stop, then automatic synchronization of upper limit
position
S.y.cL
Automatic closing taking into account safeties up to mechanical stop, followed by
automatic synchronization of lower limit position
S.y.c
Automatic closing is locked due to request Å
Status messages during dead man movement:
Hd.cL
Deadman closing (membrane key: CLOSE)
Hd.oP
Deadman closing (membrane key: OPEN)
Hd.Eu
Lower limit position reached, no further deadman closing possible
Hd.Eo
Upper limit position reached, no further deadman opening possible
Hd.Ao
Outside of permitted Eo position (no deadman opening possible)
Information messages during the parameter configuration:
noEr
Error memory: no error saved
Er--
Error memory: if error but without associated message being found
Prog