TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 68 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
15 Directives and Standards
Type tested to:
Standards:
Machinery Directive:
2006/42/EC
Device complies with Annex IV categories of machinery
–
Section 21 "logic unit for safety functions"
"EN ISO 13849-1:2008 Safety of machinery
– safety-related
parts of control systems
–part 1: General
design principles
Category: 2
Performance Level (PL): d
Safe functions:
o
Endpoint detection
o
Contacting edge evaluation (8,2/1,2 kΩ
or optical)
o
Photo eye incl. pull-in protection
(comp. EN 12453 table 1: type D or
type E with test)
o
Slip door switch
o
Slack rope switch
o
Plug-in module TST SURAx
o
Wireless safety system TST FSx
EN 62061 : 2005 Safety of machinery
–Functional safety of
safety-related electrical, electronic and
programmable electronic control systems
(IEC 62061:2005)
Safety integrity levels (SIL): 1
Low-Voltage Directive: 2014/35/EU
DIN EN 60335-1: 2012 Safety of household and similar
electrical appliances/ Part 1: General
requirements
Type: stationary motor-driven
machines
Protection class I
EN 60335-2-103:2003 Safety of household and similar
electrical appliances- - part 2-103:
Special requirements for drives for
industrial doors, doors and windows
EMC Directive: 2014/30/EEC
Electromagnetic compatibility
– basic technical standards:
EN 61000-6-1:2007 interference immunity, living area
EN 61000-6-2:2006 interference immunity, industrial area
EN 61000-6-3:2007 Electromagnetic radiation, living area
EN 61000-6-4:2007 Electromagnetic radiation, industrial area
Applied national specifications regarding
the above directives:
EN 12453:2001 Safety in use of power operated doors -
Requirements
• Chapter 5.2 Drive Systems and Power
Supply