TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 59 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
No.
Description
Possible reason for error
F.851
Max. Number of allowed
Reversings, because of bad
WiCAB radio, exceeded.
The radio connection interrupts during door drive for a short time
F.852
Communication error between TST
FSx and controller
This error occurs when the controller looses RS485 communication for min. 1 second with the stationary unit of
the radio strip TST FSx. Possible causes are:
• The stationary unit is broken
• The stationary unit is not or wrong connected
F.853
TST PE_FSBS operating voltage
too low
The operating voltage of encoder TST PE_FSBS is too low (less than 8V) As a result, the calculation of the
position must be terminated.
F.856
Communication error between
mobile and stationary unit
This error occurs if the mobile unit and the stationary unit of the radio control unit could not establish radio
communication for at least
1 second. Possible causes are:
• No mobile unit in radio range
• The battery of the mobile unit is empty or not connected
• The antenna of the stationary unit is not connected or missing
• Moile unit or stationary unit is defective
F.857
Battery empty
• The battery voltage is under the limit set with Parameter P.F0B
• The battery voltage of the mobile unit is to low
• Use new battery and set back battery capacity to 100% by pressing the stop key for long time in P.F09.
• To deactivate this error message you can set P.F09 and P.F0B to 0
F.859
Software version
The software versions of the stationary and the mobile unit are not compatible. No safe trip possible.
F.860
Internal fault stationary unit
Internal system fault on the stationary unit.
F.861
Internal fault mobile unit
Internal system fault on the mobile unit.
F.862
Internal positioning system error
Internal error of the positioning system. Presumably, the magnet is not attached properly.
F.867
Address of mobile unit not set
• The address of the mobile unit was not set so far
• The address has to be set in Parameter P.F07
• The address is written on a sticker on the mobile unit
F.910
No communication to expansion
board possible
• The communication to the expansion board is not possible
• No expansion board plugged in
• CAN Connection interrupted (Broken cable or no supply voltage for extension board)
F.911
ROM error on extension board
• Wrong Flash-Code
• Defective hardware or noise-saturated environment
F.912
RAM error on extension board
• Defective hardware or noise-saturated environment
F.920
Internal 2.5 V reference voltage
incorrect
• Hardware defect