TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 48 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
10 Movement optimisation for the door
Adjusting the pre-limit switch positions and the ramps can optimize or improve the movement of the door.
The following illustrations for OPEN and CLOSE moves show the operation of the frequency converter.
10.1 Opening of the door
Stop ramp ro
Limit switch OPEN
P.230
Pre limit switch
OPEN P.232
O
p
e
n
in
g
Limit switch CLOSE
C
re
e
p
s
p
e
e
d
F
2
P
.3
2
0
M
a
x
.
o
p
e
n
in
g
tr
a
v
e
l
s
p
e
e
d
F
1
P
.3
1
0
S
ta
rt
r
a
m
p
r
1
P
.3
1
1
/P
.3
1
2
B
ra
k
e
r
a
m
p
r
2
P
.3
2
1
/P
.3
2
2
Figure 37: Opening using frequency converter
The frequency converter starts the door movement with start ramp "r1". It accelerates from 0 Hz to the max.
travel speed.
The door is moved at the max. travel speed until the pre-limit switch for the limit position OPEN is reached.
At this point it reduces the speed of the door to creep speed using ramp "r2”. The door now moves at creep
speed until the limit switch OPEN is reached.
At this point the door is stopped (ro).