TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 29 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
5.10 Traffic light connection
Flashing red
traffic light:
flashing during
gate travel and
during
clearance time
P.701= 1253
Constant
green traffic
light:
relay active in
position Gate
OPEN
P.702= 1210
L´ L´ N´ N´
10 1112 20 2122
Jumper
blue
Figure 24: Traffic light connection
When a motor brake is being used, relay K2 is already occupied and it can not be used to control a