OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 58 of 173
H20411-0e-ID-B.docx
5.15. CFG17: Antenna Multiplexing II
The parameters in CFG17 are used to configure for multiplexing of antennas in reader automatic
mode in conjunction with antenna multiplexer ID ISC ANT.MUX.
Byte
0
1
2
3
4
5
6
Contents Mux-Valid-Time-ANT_6
Mux-Valid-Time-ANT_7 Mux-Valid-Time-ANT_8 0x00
Default 0x00C8
0x00C8
0x00C8
200 x 5ms = 1000ms
Byte
7
8
9
10
11
12
13
Contents
0x00 0x00 0x00 0x00 0x00 0x00 0x00
Default
MUX-VALID-TIME-ANT_x:
(AirInterface.Multiplexer.HF.External.Antenna.Nox.ActiveTime)
Immediately this time has expired (value x 5ms), the next antenna output is selected.
If
MUX Switch Condition
is “no response” the Reader switches from the active antenna
to the next antenna if there is no response from any Transponder on the active antenna. If
the Transponder communication time on the active antenna exceed the MUX-VALID-
TIME-ANT_x the Transponder communication on the active antenna is stopped, and the
Reader switches to the next antenna. If „
fixed
“ is selected under Switch Condition, the
switch to the next channel is always made in this time.