OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 127 of 173
H20411-0e-ID-B.docx
RSP-LENGTH:
Length of the Transponder response in bits without SOF and EOF. If the Error-Flag in the
Transponder response is set, the length of the sample data is 4 Byte.
CMD-RSP-DELAY:
Response delay for Transponder response (ISO15693: t1)
e.g. ISO15693 average value: 0x021F * 590ns = 320,4
µs
Note:
If the parameter is set to “0x0000 the default value 0x021F will be used.
EOF-PULSE-DELAY:
EOF Pulse delay is used in write operations with ISO15693 write option “1”. EOF to de-
fine the response delay for Transponder response (ISO15693: t1)
e.g. ISO15693 maximum value: 0x846A * 590ns = 20ms
REQUEST-DATA:
Complete Transponder request without SOF, CRC16 and EOF.
Note:
The read and write option FLAGS in the REQUEST-DATA must correspond to the
MODE Byte in the request protocol. Reader is always forcing the command in the
way specified by MODE Byte in the request protocol
RESPONSE-DATA:
Complete Transponder response without SOF and EOF. A CRC16 check is performed in-
side the Reader. However the Transponder CRC16 is transferred with the response data.
Notes:
•
Data is only transferred if STATUS = 0x00, 0x02, 0x83, 0x84, 0x94.
•
The response data always contains the in RSP-LENGTH defined number of da-
ta bytes.
Note:
•
This command is only available for ISO15693 Transponders.
•
This command is not available if the Scan Mode or Buffered Read Mode is
switched
on.