9.3.15. STMicroelectronics (LRI512)
IC manufacturer identifier: 0x02
memory organization: 16 x 4 Byte = 512Bit
Number of blocks
16 (user area: 0...15)
Block size
4 byte
Command
Code
Function
Mode
Comment
non
ad-
dressed
addressed select
0x01 Inventory
√
- -
-
0x02 Stay
Quiet
√
-
√
-
0x22
Lock Multiple Blocks
√
√
√
√
WR-OPTION = 0
*
0x23 Read
Multiple
Blocks
√
√
√
√
In non addressed mode DB-N
must be 1
0x24 Write
Multiple
Blocks
√
√
√
√
DB-Size = 4,
WR-OPTION = 0
*
0x25 Select
√
-
√
-
0x26
Reset to Ready
√
√
√
√
0x27 Write
AFI
√
√
√
√
WR-OPTION = 0
*
0x28 Lock
AFI
√
√
√
√
WR-OPTION = 0
*
0x29 Write
DSFID
- -
-
0x2A Lock
DSFID
- -
-
0x2B
Get System Information
-
-
-
0x2C
Get Multiple Block Security
Status
-
- -
∗
The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION para-