OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 46 of 173
H20411-0e-ID-B.docx
TR-DATA-2:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
- -
ANT_
Ext
- - - -
ANT_Ext: Antenna Extended
(OperatingMode.Buffred ReadMode.DataSelector.RSSI)
(OperatingMode.NotificationMode.DataSelector.RSSI)
b0:
no RSSI
b1:
Antenna number with RSSI
Notes:
If Antenna Extended is enabled the bit for number of antenna must be disabled
TR-DATA-3:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
- - -
READ_
COMPL
ETE_
BANK
- - -
COM-
PREFIX
COM-PREFIX: (Scan Mode only)
(OperatingMode.ScanMode.DataFormat.BusAddressPrefix)
b0:
no COM Prefix is send
b1:
The Reader will transmit the COM-ADR in front of each data set.
READ_COMPLETE_BANK:
(OperatingMode.ScanMode.DataSelector.Mode.Read_Complete_Bank)
(OperatingMode.BufferedReadMode.DataSelector.Mode.Read_Complete_Bank)
(OperatingMode.NotificationMode.DataSelector.Mode.Read_Complete_Bank)
If this bit is set the reader will read out all memory blocks from the selected Memory
BANK.
b00
Reader reads out the memory blocks according to the settings in DB-
ADR, DB-N, D-Start and D-LGT.
b01
Reader reads out all blocks of the selected memory bank