5.21. CFG40: LAN Settings, Part 1
Byte
0
1
2
3
4
5
6
Contents
IP_ADDRESS_LAN
-
-
-
Default 0xC0
0xA8
0x0A
0x0A
0x00
0x00
0x00
192 168 10 10
Byte
7
8
9
10
11
12
13
Contents
-
IP_PORT_NUMBER_LAN
-
-
- -
Default
0x00 0x27 0x11 0x00 0x00 0x00 0x00
10001
IP_ADDRESS_LAN: (HostInterface.LAN.IPv4.IPAddress)
Defines the IP address for wired LAN connection. Changing of this parameter only be-
comes effective after writing / saving this configuration block to EEPROM and a [0x64] Sys-
tem Reset of the LAN-adapter.
IP_PORT_NUMBER:_LAN (HostInterface.LAN.PortNumber)
Defines the port number for wired LAN connection. Changing of this parameter only be-
comes effective after writing / saving this configuration block to EEPROM and a [0x64] Sys-
tem Reset of the LAN-adapter.