10.5. [0x31] Read Data Buffer Info
The command Read Data Buffer Info reads the actual parameters of the data buffer.
Host
→
Reader
1
2
3
4
5
6...7
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR [0x31] CRC16
Host
←
Reader
1
2
3
4
5
6
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR [0x31] STATUS
©
7...8
9,10
11,12
13,14
ª
TAB-SIZE TAB-START TAB-LEN
CRC16
TAB-SIZE:
Maximum count of Transponder data sets in the data buffer.
TAB-START:
Address of first Data Set in the data buffer.
TAB-LEN:
Number of Transponder data sets reserved in the data buffer.
Notes:
•
Additional information about the data table status is transferred if STATUS = 0x00, 0x84,
0x85, 0x93.
23