OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 112 of 173
H20411-0e-ID-B.docx
8.1.7. [0x26] Reset to Ready
This command sets one Transponder to Ready State.
REQUEST-DATA
6
7
(8...15)
0x26 MODE UID
RESPONSE-DATA (STATUS = 0x95)
7
ISO15693
ERROR
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0 0 0 0 0
ADR
ADR:
b000 non-addressed
b001 addressed
b010 selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS
= 0x95.
Note:
•
This command is only available for ISO15693 Transponders.