OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 44 of 173
H20411-0e-ID-B.docx
5.9. CFG11: Read Mode / Read Data
The parameters of the CFG11 configuration block contain settings for a reader automatic mode. To
enable a reader automatic mode (Buffered read Mode, Scan Mode, Notification Mode), the accord-
ing bit in the READER-MODE register of the configuration block
must be set.
It is useful to enable “Anticollision Select Mode” in
if there is a large or unknown number of Transponders in the antenna field.
The reader automatic mode can be used with the Antenna Multiplex Mode, the parameters for this
function have to be configured in
5.13. CFG15: Antenna Multiplexing I
and
Byte
0
1
2
3
4
5
6
Contents
TR-DATA-1
TR-DATA-2
TR-DATA-3
Bank
DB-ADR
0x00
Default
0x01 0x00 0x00 0x03
0x0000
Byte
7
8
9
10
11
12
13
Contents
0x00
DB-N
EAS-MODE D-START
D-LGT
Default
0x0001
0x00 0x00
0x04
TR-DATA:
(OperatingMode.ScanMode.DataSelector.Selector)
(OperatingMode.NotificationMode.DataSelector.Selector)
(OperatingMode.BufferedReadMode.DataSelector.Selector)
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
Exten-
sion
- TIMER
ANT Byte
Order
DB
EAS DB SNR
SNR
(OperatingMode.ScanMode.DataSelector.Uid)
(OperatingMode.NotificationMode.DataSelector.Uid)
(OperatingMode.BufferedReadMode.DataSelector.Uid)
b0:
no Serial Number will be stored
b1:
Serial Number will be stored
DB
(OperatingMode.ScanMode.DataSelector.Data)
(OperatingMode.NotificationMode.DataSelector.Data
(OperatingMode.BufferedReadMode.DataSelector.Data)
b0:
no data block will be stored
b1:
data block will be stored