7.7. [0x6A] RF Output ON/OFF
The command RF ON/OFF switches the RF field of the Reader antenna ON and OFF.
If the reader works in Auto Read Mode
the RF communication can be interrupted by transmitting RF OFF and contin-
ued with RF ON. After RF OFF, the reader accepts every Host command and the RF communication is handled on the
last selected antenna. For selecting a specific antenna without continuing the Auto Read Mode, the option flag HM must
be set.
Host
→
Reader
1
2
3
4
5
6
7,8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR [0x6A] RF-Output CRC16
Host
←
Reader
1
2
3
4
5
6
7,8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR [0x6A] STATUS
CRC16
RF-OUTPUT:
Set RF and DC power of the antenna output.
Bit:
7
6
5
4
3
2
1
0
Function
HM
0 0 0 0 0 0 RF
RF
Set RF output active or RF Power OFF
RF
Description
b0 RF
OFF
b1 RF
ON
HM
Maintain Host Mode (applicable only for Auto Read Mode)
b0: Auto Read Mode is continued, if Antenna Output is greater than zero
b1: Host Mode is maintained and Antenna Output is selected, if greater than zero