OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 123 of 173
H20411-0e-ID-B.docx
9.1.2. [0xB3] [0x22] Lock
This command Lock different memory portions of a ISO18000-3M3 Transponder.
REQUEST-DATA
6
7
1 Byte
EPC_LNG
Bytes
0x22 MODE
EPC_LNG
EPC
©
1 Byte
1 Byte
LOCK_LNG
Bytes
1 Byte
A_PW_LNT
Bytes
ª
EPC_TYPE LOCK_LNG LOCK_DATA A_PW_LNG
A_PW
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0 EPC_LF 0
ADR
ADR:
b000 non-addressed
b001 addressed
EPC_LF:
If this bit is set the parameter EPC_LNG must inserted into the protocol.
b1:
The protocol includes the parameter EPC_LNG. The EPC has a variable
length as defined in EPC_LNG.
EPC_LNG:
Is a optional parameter and depends on the setting of EPC_LF (see MODE). EPC_LNG
defines the length of the following EPC field.
EPC:
Read-only serial number of the Transponder. The EPC is required only in the addressed
mode.
EPC_Type:
Type of Transponder according
ANNEX A: Codes of Transponder Types.
LOCK_LNG:
Length of LOCK_DATA Field
LOCK_DATA:
Lock data which will be written to the Tag.
A_PW_LNG:
Length of Access Password.