OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 31 of 173
H20411-0e-ID-B.docx
Note:
•
Changing of TRANS-FORM only becomes effective after writing configuration
block CFG1 to EEPROM and reset of the Reader.
•
Always 8 Data Bits and 1 Stop Bits should be used
TR-RESPONSE-TIME: (AirInterface.TimeLimit)
By means of this parameter the maximum duration for the Transponder command can be
defined.
The TR-RESPONSE-TIME starts after the Reader has received a new command. At the
latest after the TR-RESPONSE-TIME elapsed the Reader will send an answer protocol. In
this case, the current commands between Reader and Transponder are aborted. If this
time is to short the Interface Status “ 0x83 RF Communication Error“ will appear.
max. response duration
TR-RESPONSE-TIME
0...65535 * 5 ms
Note:
•
TR-RESPONSE-TIME has no effect with the protocols for Reader Configuration and
the protocols for Reader Control.
•
The TR-RESPONSE Time must be < “Block Timeout” in the Host COM-Port settings.
SCAN-INTERFACE: (OperatingMode.ScanMode.Interface)
Selection of the communication port for Scan-Mode
Bit:
7
6
5
4
3
2
1
0
Function: -
-
DC
Format
IF-NO
IF-NO:
Interface Number
b000: RS232
b010:
USB
b1xx:
- do not use -
Note:
•
The reader with USB interface in Scan Mode works like a Human Interface Device
(HID).
•
The reader with USB interface in Scan Mode sends the data in USB-Keycode.