OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 131 of 173
H20411-0e-ID-B.docx
9.3.4. Fujitsu (MB89R118)
IC manufacturer identifier: 0x08
Chip ID: 1h = 00000001b (Bit 47 - 40 of UID)
Memory organization: 256 x 8 Byte = 16kBit
Number of blocks
256 (user area: 0 – 249)
Block size
8 byte
Command
Code
Function
Mode
Comment
non-
addressed
addressed select
0x01 Inventory
√
-
-
0x02 Stay
Quiet
√
-
√
-
0x22
Lock Multiple Blocks
√
√
√
√
WR-OPTION = 0 or 1
0x23
Read Multiple Blocks
*
√
√
√
√
Security Status is always
0x00
0x24
Write Multiple Blocks
**
√
√
√
√
WR-OPTION = 0 or 1
0x25 Select
√
-
√
-
0x26
Reset to Ready
√
√
√
√
0x27 Write
AFI
√
√
√
√
WR-OPTION = 0 or 1
0x28 Lock
AFI
√
√
√
√
WR-OPTION = 0 or 1
0x29 Write
DSFID
√
√
√
√
0x2A Lock
DSFID
√
√
√
√
0x2B
Get System Information
√
√
√
√
0x2C
Get Multiple Block Security
Status
√
√
√
√
*
The Custom Specific Commands Read Multiple Blocks Unlimited [0xA3] will be used automatically by the
Reader. In non addressed Mode only one or two blocks can be read and the parameter DB-Blocksize in
“CFG4 Transponder Parameters” should be set to 8.
**
The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter is set to “00:
automatically set” in “CFG4 Transponder Parameters”. Up to two blocks of data can be written for one re-
quest.
•
10% Modulation and ASK SUB-CARRIER and Datacoding 1 of 4 must be configured in the reader.