OBID
i-scan
®
HF System-Manual
ID
ISC.LR1002
FEIG ELECTRONIC GmbH
Page 38 of 173
H20411-0e-ID-B.docx
5.5. CFG4: Transponder Parameters
The parameters of the CFG4 configuration block contain general Transponder settings.
Byte
0
1
2
3
4
5
6
Contents
0x00 0x00 0x00 0x00
ISO 15693
MODE
ISO 15693
AFI1
ISO15693
OPTION
Default
0x0B
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents 0x00
ISO 15693
AFI2
ISO 15693
AFI3
ISO 15693
AFI4
TID-LENGTH
IDDIB
ISO-
Blocksize
Default
0x00
0x00
0x00
0x04
ISO 15693 MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0 0
AFI
NO-TS
DATA-
RATE
0 0 0
DATA-RATE
b0
- do not use -
b1 high
NO-TS (Transponder.HF.ISO_15693.Anticollision.NoOfTimeslots)
b0 16
timeslots
b1 1
timeslot
AFI (Transponder.HF.ISO_15693.SelectionMask.Enable_AFI)
b0 Disabled
b1 Enabled
ISO 15693 AFI1:
(Transponder.HF.ISO_15693.SelectionMask.AFI1)
First
Application Family Identifier to select a Transponder
ISO 15693 OPTION:
Bit:
7
6
5
4
3
2
1
0
Function
0 0 0 0 WR-OPTION 0 0
WR-OPTION: (Transponder.HF.ISO_15693.Miscellaneous.WriteOption)
b00: automatically
set
b10:
Tag Option = 0
b11:
Tag Option = 1