Operating
8.5
Start after a service
5.
Check the current to the separator motor to
ensure that the separator has reached full
speed: During start, the current reaches a peak
and then slowly drops to a low and stable value.
For normal length of the start-up period see
7.3
Technical Data on page 133
.
Current increases during start...
... to decrease to a stable value when full speed
has been reached
6.
For
purification
:
a. Supply water to form the water-seal. The
water should have the same temperature as
the process liquid.
b. Close the water feed when water flows out
through the water outlet.
c. Start the oil feed slowly to avoid breaking
the water seal.
7.
For
clarification
:
a. Start the oil feed with full flow.
8.
For both
purification
and
clarification
modes:
Check the separator inlet and outlet pressures.
See recommended values in your system
documentation.
9.
Adjust to desired throughput.
8.5.3
Separation
Do regular checks on:
•
oil inlet temperature (if applicable)
•
water collecting tank level (if applicable)
•
sound/vibration of the separator
•
back pressure
•
motor current