7.6
Interface Description
7
Technical Reference
Signal processing in
STOPPING
:
•
If the self check system triggers, an alarm shall
be given..
Signal processing in
NORMAL STOP
:
•
If to high vibrations occur the system shall turn
over automatically to
SAFETY STOP
.
Fluid connections
Complementary information is given in the
document Connection List.
201 Inlet for process liquids (feed).
Processing in
STAND STILL
:
•
Shall be closed.
Processing in
STARTING
:
•
Should be closed. Bowl will be open and empty
or closed and filled depending on if start is done
from
STAND STILL
or
STOPPING
.
Processing in
RUNNING
:
•
Could be closed or open.
•
Shall be closed before a discharge. See
8.2.1
Operating water interface on page 168
or
8.3.1
Operating water interface on page 169
.
Processing in
NORMAL STOP
or
EMERGENCY
STOP
:
•
Could be closed or open but the bowl should be
filled unless the stop is initiated in
STARTING
.
Processing in
SAFETY STOP
:
•
Could be closed or open but the bowl shall be
filled unless the stop is initiated in
STARTING
.
206 Inlet to liquid seal.
Processing in
STAND STILL
:
•
Shall be closed.
Processing in
STARTING
:
•
Shall be closed.
Processing in
RUNNING
:
•
Supplying a liquid seal prior to opening the feed:
See Operating water interface.
142
www.fdm.com.pe
Содержание P 605
Страница 8: ...ventas fdm com pe fdmsac gmail com whatsapp 959440045 www fdm com pe...
Страница 18: ...ventas fdm com pe fdmsac gmail com whatsapp 959440045 2 Safety instructions www fdm com pe...
Страница 77: ...ventas fdm com pe fdmsac gmail com whatsapp 959440045 6 Dismantling Assembly www fdm com pe...