[email protected]
whatsapp:959440045
7.4
Connection list
7
Technical Reference
7.4
Connection list
Alfa Laval ref. 561658 Rev. 1
Connection
Description
Requirements/limits
No.
201
Inlet for process liquid
- Flow
See
7.11 Performance data, in- and
- Pressure
See
7.11 Performance data, in- and
206
Inlet for liquid seal and displacement
liquid.
- Quality requirements:
See
- Flow, set value:
8 litres/minute
220
Outlet for light phase, clarified liquid
- Counter pressure
See
7.11 Performance data, in- and
- Capacity
See
7.11 Performance data, in- and
(221)
Outlet for heavy phase
Should be possible to drain liquids
by gravity.
222
Outlet for solid phase
- Discharge volume:
See
7.3 Technical Data on page
133
. The outlet after the separator
should be installed in such a way
that you can not fill the frame top
part with sludge. (Guidance of
sludge pump or open outlet)
372
Inlet for discharge liquid.
- Flow, set value:
18 litres/minute
- Quality requirements:
See
373
Inlet for make-up liquid.
- Flow, set value:
0,9 litres per minute
- Quality requirements:
See
7.7 Water quality on page 145
- Consumption:
0,9 litres per discharge
377
Outlet for operating liquid.
Should be possible to drain liquids
by gravity.
462
Drain of frame top part, lower
Should be possible to drain liquids
by gravity.
463
Drain of frame top part, upper.
Should be possible to drain liquids
by gravity.
701
Motor for separator
- Allowed frequency variation
± 5%
(momentarily during 5 seconds)
± 10%