![FBII XL-4 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/fbii/xl-4/xl-4_installation-and-setup-manual_3747328048.webp)
Xl-4, XL-4B, and XL-5 Hookup and Installation Instructions
Version 4
6–2
Time Date Setup Procedure
CODE [INSTALLER CODE] 2
This will generate similar keypad displays as the end user procedure. See time/date section
for more details.
Walk Test
The walk test function provides the ability to test the zones that have been programmed
within the system. The walk test has options to display the zones that require testing as well
as displaying the zones that have been tested.
The zones to be tested during the walk test will depend on the system. Based on the system
expansion module installed, the following zones will be tested:
No expander
Zones 1–8 only
7015 (Hardwired expansion)
Zones 1-16
7120 expander (XL-4/XL-B)
Zones 1 - 72 (Zones 1-8 Hardwired, zones 9-72 multiplex)
7126 expander (XL-5)
Zones 1 - 128 (Zones 1-8 Hardwired, zones 9-128
multiplex)
Walk Test Procedure
CODE
✴
[INSTALLER CODE] 3
Depress the CODE key followed by the
✴
key, and your six-digit installer code. A display will
appear indicating that you have entered the installer walk test mode.
The following display will appear:
WALK TEST MODE
WALK TEST
Zne 004
MASTER BEDROOM
The initial walk test mode will scroll through a list of the zones that have not been tested.
The first line of the display shows the zone number and the second line contains the zone
description. The zones included in the list depend on the programming option for zone
expansion. Note: If the multiplex expander module is present (model 7120 or 7126) then the
zones tested will depend on the zone expansion option selected.
At this point the individual zones can be tripped to test their operation. As each zone is
violated the keypad will emit a sound every time a zone has been violated and/or restored. As
each zone is tested the zone will be removed from the scrolling loop of zones that have not
been tested.
Walk test can only be performed on LCD keypads.
The walk test mode will automatically terminate after approximately 5 minutes without any
testing activity and the system will return to the previous system status.
Display Tested Zones
To display the zones already tested press the # key. This will scroll through the zones that
have already been tested as follows:
Tested
Zne 006
DINING ROOM
In this mode the keypad will scroll the zones that have already been tested. Depression of the