Xl-4, XL-4B, and XL-5 Hookup and Installation Instructions
Version 4
5–16
2) Press 2. The keypad will display:
Su AUTOARM HR
12:00 a Part 1
The Part number will be the partition number the keypad is enabled in.
3) Set the hour by entering a number from 1 to 12 for the desired hour (HR).
4) Press the Instant key. The HR portion of the display will change to MIN.
5. Set the minute by entering a number from 0 to 59 for the desired minute (MIN).
6) Press the Code key to change from AM (a) to PM (p).
The CODE key must be depressed at least one time during this procedure. If the key has not
been depressed at least once, you will not be able to exit when you enter the
✴
at the end of this
procedure.
7) Press the Stay key to advance to the desired day of the week. Note that if the # key is
pressed while in the auto arm mode, the display will show --:-- meaning that the time is
disabled and there will be no auto arm for that day.
8) When all entries have been completed, press the
✴
to exit.
Zone Directory [# 4]
The LCD keypad can display descriptors of the zones connected to the system. To view the
zone descriptors for your system simply press # 4 and the system will scroll the descriptors
on the keypad. This command will display the descriptors for the zones associated with your
partition only. To exit from the zone directory function, press any key from the keypad.
Quick Bypassing [# 5]
Bypassing can also be performed without entry of a user code through entry of # 5 followed
by the three-digit zone number. For example to bypass zone 13 enter # 5 0 1 3. Note: The
zone selected must be bypassable.
Chime Mode [# 6]
The system contains an optional chime feature which causes the keypad sounder to activate
for one second every time selected zones such as an entrance door is opened while the system
is disarmed. For example, this could be used to inform the end user each time that a selected
opening such as an entrance door or patio door was opened. There is a programmable option
per zone to select whether each zone can participate in the chime. To activate the chime
feature Press # 6 then 0 to turn the chime mode on or off.
The LCD display shows the current CHIME status as follows:
CHIME is now ON
0 = OFF
✴
= exit
In this example entry of a 0 will turn the system chime mode off, or the
✴
key will exit from
the function.
Partition Assignment [ # 7 ]
The system has the ability to be broken into separate independent subsystems known as
partitions. Each user code can be valid in one or more partitions. Normally partition
assignments are made by the installer through any of the programming methods during the