Section 5 – System Operations
5–7
ON: AWAY INSTANT
On LED keypads both the ARMED and INSTANT LEDs will be lit.
The INSTANT option will automatically be reset after the system is disarmed. The second
line of this display can scroll between various system conditions such as zones that are
currently bypassed.
Instant-Stay
The INSTANT-STAY mode will arm the system with the characteristics of both the INSTANT and STAY
modes. The system will be armed with the interior portions bypassed and the entry and exit delays will be
suspended.
The system must be READY in order to perform this function.
Instant-Stay Procedure
INSTANT STAY [USER]
or
STAY INSTANT [USER]
After a successful INSTANT STAY arming the armed indicator will be lit and the following
display will appear on LCD displays:
ON: STAY INSTANT
On LED keypads the ARMED, STAY and Instant LEDs will be lit.
Bypass
Bypasses are performed to exclude burglary zones that are faulty or not ready from
activating the system. In order to bypass a zone, the zone definition must specify that the
zone can be bypassed. In addition, the user performing the bypass must be authorized for
bypass (levels 1, 2, 3 or 4).
Bypassing is only permitted if there are no alarms or latched troubles present in the system.
In addition, a zone cannot be unbypassed if its current state would put the zone into an
alarm state.
Bypass Procedure
BYPASS [USER] ZN
where:
ZN Three digit zone number.
For example to bypass zone 17 enter;
BYPASS [USER] 017
Multiple zones may be bypassed by repeating the sequence for the desired zones within a
fifteen-second interval as shown in the following example:
BYPASS [USER] 002 BYPASS 043 BYPASS 055 Bypass zones 2, 43, and 55
If a zone entered is already bypassed, the sequence will unbypass the zone except if the
system is armed and the bypassed zone is still not ready.
After a bypass or unbypass command has been accepted the LCD keypad will emit a
continuous beep and display;
BYPASSED Zne 002
UPSTAIRS BEDROOM
or