![FBII XL-4 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/fbii/xl-4/xl-4_installation-and-setup-manual_3747328040.webp)
Xl-4, XL-4B, and XL-5 Hookup and Installation Instructions
Version 4
5–12
Disarming
To disarm the system from an armed state:
Disarming Procedure:
[USER]
Enter a valid user code.
The keypad display that appears on LCD keypads depends whether or not alarms have taken
place while the system was armed.
A) IF NO ALARMS HAVE TAKEN PLACE
The system disarming will optionally remove all bypasses and the ARMING indicator will
go off. The system display will reflect the current status.
B) IF ALARMS HAVE TAKEN PLACE
If alarms or other conditions have taken place since the initial system arming, they will
appear on the display. The alarm(s) that have occurred will scroll on LCD keypads
approximately every two seconds in time sequence as shown in the sample displays below;
BURGLARY
zn012
MASTER BEDROOM
BURGLARY
zn055
LIVING ROOM
FIRE
zn004
MAIN HALLWAY
After scrolling through the alarms, the display will return to the first condition and
repeat the sequence of alarms until the system is cleared.
On LED keypads the zones that were in alarm will pulse rapidly. To acknowledge the
conditions and clear the display of the alarm signals enter [USER] again, or the
✴
key if
the RESET function has been enabled.
Keypad Auxiliary Conditions
In addition to individual zone alarms the control panel contains three programmable keypad
aux. conditions. These conditions are initiated through the depression of two keys as listed
below:
The keypad auxiliary conditions are active 24 hours a day.
The three keypad conditions can be initiated as follows:
CONDITION
KEYSTROKES (ALL KEYPADS)
ADDITIONAL COMBINATIONS
USING XK-516 or XK-5LC KEYPAD
EMERGENCY KEYS
FIRE
3 + # or 7 + 9
Left 2 Keys
MEDICAL
1 +
✴
, 1 + 3, or 4 + 6
Middle 2 Keys
PANIC
✴
+ #
Right 2 Keys
Note: + indicates the simultaneous depression of the two keys shown. For example, 3 + #
indicates pressing the 3 and # keys at the same time.