![FBII XL-4 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/fbii/xl-4/xl-4_installation-and-setup-manual_3747328041.webp)
Section 5 – System Operations
5–13
Duress/Ambush
The system contains duress capability, which can be obtained through use of a user code with
an authorization level of 6. The duress feature will report to the Central Station based on the
parameters defined as keypad condition number 4.
LCD Keypad Programming Mode
Installer programming can be performed through a LCD keypad to view or modify the
programmable characteristics of the control panel. Entry into this mode will obtain
numbered displays corresponding to the programming questions. Within the programming
mode the installer can scroll through the questions sequentially or directly access any
question. Full details on keypad programming can be found in the LCD Keypad
Programming Guide.
Quick Commands
The system contains some quick command functions that can be enabled or disabled through
the programming sequence. These commands can be initiated by the end user through
depression of the # key followed by the command number (and CODE key for Multi-Partition
Mode) as shown below;
SEQUENCE
COMMAND
# 0 CODE
Keypad Common Partition Display
# 1
Quick Arming
# 2
Quick Forced Arm
# 3
Time/Date Set and Auto Arming
✴
# 4
LCD Zone Directory
✴
# 5
Quick Bypass
# 6
Chime On/Off
# 7
User Partition Assignment
✴
✴
LCD Keypads Only
Each of the quick arming commands can be enabled or disabled through programming options.
Keypad Common Partition Display [# 0 CODE]
The control panel can be configured to appear as multiple separate security systems. Each
subgroup is known as a partition and users can be valid in different partitions. Each
partition would contain its own zones and keypads and would normally be operated
independently.
The keypad common partition display allows authorized users to view the status of all
partitions and to perform functions to their assigned partition from any keypad within the
entire system. The user will only be able to perform the functions authorized for that user.
To enter the keypad common partition display, enter # 0 followed by a valid user code. LCD
keypads will display:
ENTER PART (0 - 9)
# VIEW,
✴
EXIT
Next enter the desired partition. Note: The user must be authorized within the requested
partition. Entry of 1 - 8 will return with the keypad displaying the status of the requested
partition. At this point the user can perform any of the regular keypad functions, within the