Xl-4, XL-4B, and XL-5 Hookup and Installation Instructions
Version 4
5–6
STAY
The STAY mode will ARM the system and deactivate any interior protection zones that exist
within the system. In order to perform the STAY function the system must be ready. See
description of READY state within ARMING sequence.
Stay Procedure
STAY [USER]
Depress the STAY key followed by any valid four-digit user code.
Following a successful STAY arming the following display will appear on LCD keypads:
ON: STAY . . . . . . .
. . . Exit now . . .
The EXIT NOW message will appear on the second line of the display for the duration of the
exit delay. In addition the ARMED indicator will be lit. The second line of the display may
scroll through zones that have been bypassed.
On LED keypads both the ARMED and STAY indicators will be lit.
An option exists within the programming sequence to determine whether bypasses are
transmitted to the CS when performing STAY arming.
Auto Stay
The Auto Stay mode will ARM the system bypassing selected zones which have been defined
as Auto Stay zones. Auto Stay zones are burglary zones with Bypass and Auto Stay enabled.
Auto Stay is enabled in the same manner as AWAY except, the entry/exit door must not be
opened during the exit delay period.
Auto Stay Procedure
[USER]
Enter any valid four-digit user code. In order to arm the system the user must be defined as
a valid user within the partition. Following a successful entry, the following display will
appear on LCD keypads:
ON: AWAY . . . . . . .
. . . Exit now . . .
The ARMED indicator will now be lit. The message on the display will appear for the
duration of the exit delay. DO NOT PASS THROUGH AN ENTRY/EXIT ZONE DURING
THE EXIT DELAY. At the end of the exit delay, the following display will appear on LCD
keypads:
ON: AUTO STAY
INSTANT
The INSTANT mode ARMS the system and eliminates the entry and exit delay time period.
This mode should be used when the violation of any protected zone should cause an instant
alarm.
The system must be READY to perform the INSTANT function.
Instant Procedure
INSTANT [USER]
Upon successful INSTANT arming of the system the ARMED indicator will be lit and the
following display appears on LCD keypads: