![FBII XL-4 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/fbii/xl-4/xl-4_installation-and-setup-manual_3747328015.webp)
Section 3 – System Wiring and Hookup
3–7
The first three switches (SW1 - SW3) should be set as follows:
KEYPAD NUMBER
LCD
SW1
SW3
1
9
ON
ON
ON
2
10
OFF
ON
ON
3
11
ON
OFF
ON
4
12
OFF
OFF
ON
5
13
ON
ON
OFF
6
14
OFF
ON
OFF
7
15
ON
OFF
OFF
8
16
OFF
OFF
OFF
On XK-716 and XK-7LC keypads, when the right hand side of the switch is pushed in the
switch is in the ON position. When the left-hand side of the switch is pushed in the switch is
in the OFF position. On XK-516 and XK-5LC keypads, when the switch is pushed toward the
back of the keypad the switch is in the ON position. When the switch is pushed toward the
front of the keypad the switch is in the OFF position.
The system should always be powered down and when changing dip switches or hooking up
keypads.
OFF
1 2 3 4
1
2
3
4
ON
XK-5LC AND XK-516 BOTTOM VIEW (WITH BACK REMOVED)
XK-7LC AND XK-716 FRONT VIEW (WITH COVER OPEN)