SMX System MultiMatrix Switcher • SIS Configuration and Control
58
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Set e-mail recipient
E
X8@
,
X8!
CR
}
Ipr
X8@
,
X8!
,
]
Sets e-mail address to account
X8@
.
Read e-mail recipient
EX8@
CR
}
X8!
,
]
Read e-mail address of account
X8@
.
Set e-mail events for recipient
EX8#X8@
,
X9)
,
X8$
,
X8%
EM
}
X9)
Ipe
X8#
,
X8@
*
X8$
*
X8%
...
X8%]
Example:
E
I65,02,00,2EM
}
02IpeI65*00*2222222222222222
]
View e-mail events for
recipient
EX8#X8@
,
X9)
,
X8$
EM
} X8%X8%X8%
...
X8%]
Set serial port parameters
E
*
X5!
,
X6^
,
X6&
,
X6*
,
X6(
CP
}
Cpn
X5!
Ccp
X6^
,
X6&
,
X6*
,
X6(]
Read serial port parameters
EX5!
CP
}
X6^
,
X6&
,
X6*
,
X6(]
Set mode
EX5!
*
X7)
CY
}
Cpn
X5!•
Cty
X7)]
Sets port
X5!
for RS-232 or RS-422
control.
Read mode
E
CY
}
X7)]
Set current conn port timeout
E
0*
X8*
TC
}
Pti0*
X8*]
Read current conn port
timeout
E
0TC
}
X8*]
Configure global IP port
timeout
E
1*
X8*
TC
}
Pti1*
X8*]
Read global IP port timeout
E
1TC
}
X8*]
NOTES:
X5!
= Specific port number
01
-
02
X6^
= Baud rate:
9600
= default
19200
38400
115200
X6&
= Parity:
O
= odd
E
= even
N
= none
M
= mark
S
= space
X6*
= Data bits
7
,
8
X6(
= Stop bits
1
,
2
X7)
= Port type
0
= RS-232 (default)
1
= RS-422
X8!
= E-mail recipient address
X8@
= E-mail Account
65
-
72
X8#
= Notification Selection 1
I
= inputs
F
= fans
P
= power supply
X8$
= Notification Selection 2
If
X8#
=
I
, then
X8$
=
00
(all inputs), or
1
-
16
If
X8#
=
F
, then
X8$
=
00
(both fans),
01
(fan 1), or
02
(fan 2)
If
X8#
=
P
, then
X8$
=
00
(both power supplies),
01
(PS 1), or
02
(PS 2)
X8%
= Notify when ?
0
= No response
1
= Failed or Missing
2
= Fixed or Restored
3
= Both 1 and 2
4
= suspend
5
= Un-suspend
X8*
= The number of seconds x10
1
-
65000
= 10 - 650,000 seconds
before timeout on IP connections
30
= default (300 seconds)
X9)
= Slot address
00
= fan and power supply
01
-
10
= inputs