SMX System MultiMatrix Switcher • SIS Configuration and Control
56
Command/Response Table for IP SIS Commands
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
IP Setup Commands
Set unit name
EX5$
CN
}
Ipn
•
X5$]
Reset unit name to factory
default
E
•
CN
}
Ipn
•
X5(]
Read unit name
E
CN
}
X5$]
or
X5(]
Set time and date
EX5%
CT
}
Ipt
•
X5%]
See
Symbol Definitions
on page 53
for more details.
Read time and date
E
CT
}
X5%]
Set GMT offset
EX5@
CZ
}
Ipz
X5@]
NOTE:
In the command, the divider between hours and minutes can be either a colon or a period. In the response,
the divider is a colon.
Example:
E
8.0CZ
}
Ipz+08:00
]
Read GMT offset
E
CZ
}
X5@]
Set Daylight Saving Time
EX7%
CX
}
Ipx
X7%]
Read Daylight Saving Time
E
CX
}
X7%
]
Set DHCP on
E
1DH
}
Idh1
]
Set DHCP off
E
0DH
}
Idh0
]
NOTE:
Setting DHCP from on to off will reset the IP address to factory default (192.168.254.254).
View DHCP mode
E
DH
}
X5#]
Set IP address
EX5^
CI
}
Ipi
•
X5^]
Read IP address
E
CI
}
X5^]
Read hardware address (MAC)
E
CH
}
X5*]
Iph
•
X5*]
00-05-A6-
xx-xx-xx
= MAC
address
Verbose mode 2 and 3
Read # of open connections
E
CC
}
X8(]
0
-
200
= number of open
connections
NOTES:
X5@
= GMT offset –12.0 t14.0 hours and minutes removed from GMT
X5#
= DHCP mode status
0
= off or disabled
1
= on or enabled
X5$
= Unit name Text string up to 24 characters (A-Z, 0-9, and "-").
Not case sensitive.
X5%
= Time and date (set and read)
MM/DD/YY•HH:MM:SS
X5^
= IP/Gateway address
nnn.nnn.nnn.nnn
, Factory default IP address: 192.168.254.254
X5*
= Hardware (MAC address)
nn.nn.nn.nn.nn.nn
X5(
= Default Name Combination of model name and last 3 pairs of MAC address
(SMX-00-02-3D)
X7%
= Daylight savings time
0
= Daylight Savings Time off or ignore
1
= Daylight Savings Time on (USA)
2
= Daylight Savings Time on (Europe)
3
= Daylight Savings Time on (Brazil)
X8(
= Number of open connections
0
-
200