SMX System MultiMatrix Switcher • HTML Configuration and Control
103
EDID configuration
1.
In the Plane section, select the plane that has an EDID-supporting output board installed.
2.
In the EDID Configuration section, click the applicable Input number and scroll down to
the resolution and refresh rate desired (see
figure 62
, input 7).
NOTE:
The drop-down list has 41 selections (see the
EDID table
on page 41).
Figure 62.
EDID Configuration Settings
3.
If using
User Assigned 1
-
4
, click one of the
Save Output 1 User
button (1-4) as
desired. The DDC data is saved under the User Assigned number for recall.
4.
To save an EDID setting to a user assignable number (User Assigned 1 through 4),
connect the monitor (that you want the EDID data for) to Output 1 only and turn on the
monitor.
5.
Press a User button to save the data. The saved data can be recalled later.