SMX System MultiMatrix Switcher • SIS Configuration and Control
54
X6#
= Verbose mode
0
= clear/none
(default for Telnet connections)
1
= verbose mode (default for RS-232
and RS-422 connections)
2
= tagged responses for queries
3
= verbose mode and tagged for
queries
X6^
= Baud rate
9600 (default), 9200, 38400, 115200
X6&
= Parity
O = odd
E = even
N = none
M = mark
S = space
X6*
= Data bits
7, 8
X6(
= Stop bits
1, 2
X7)
= Port type
0 = RS-232 (default)
1 = RS-422
2 = RS-485
X7#
= Web page priority flag
0 = internal (default factory reset)
1 = user
X7$
= Password
12 digits, alphanumeric
User or admin
NOTES:
•
The following characters are invalid or not recommended in the name:
~ , @
= ' [ ] { } < > ` " ; : | \ ?
and
space
•
User password cannot be assigned if no admin password exists (returns error
code
E14
). When admin password is cleared, then user and all security level
passwords are deleted.
X7%
= Daylight Savings Time
0
= Daylight Savings Time off or ignore
1
= Daylight Savings Time on
(USA - April to October)
2
= Daylight Savings Time on
(Europe - March to October)
3
= Daylight Savings Time on
(Brazil - October to March)
X7^
= Event number
0
-
99
Event must be running.
X7&
= Event data size
b
= bit
B
= byte (8 bits)
S
= short (16 bits)
L
= long (32 bits)
NOTE:
The parameter is case sensitive and may be optionally preceded by
A
(And) or
O
(Or) to logically combine with content instead of replacing it.
X7(
= Number of bytes to read
1
-
127
X8)
= E-mail event number or mailbox
1
-
64
Response is 3 digits with leading zeros.
X8!
= E-mail recipient address
X8@
= E-mail account
65
-
72