7847FSEDA Series
Frame Synchronizer and Distribution Amplifier
Revision 0.1
Page - 57
Loudness Range Low:
This field displays the lowest calculated loudness value within the duration of
the
Integrated Loudness
calculation, given the exclusions and thresholds used as described above in
the calculation of the
Loudness Range
. This control is used for monitoring purposes only. The value
is reported in LUFS
Loudness Range High:
This field displays the highest calculated loudness value within the duration
of the
Integrated Loudness
calculation, given the exclusions and thresholds used as described above
in the calculation of the
Loudness Range
. This control is used for monitoring purposes only. The
value is reported in LUFS
Reset:
This control allows the user to flush the buffer for the
Integrated Loudness
calculation. This
control should be activated each time a new
Integrated Loudness
value is to be obtained.
Start/Continue:
This control allows the user to commence or resume the duration in which loudness
values are being used to calculate the
Integrated Loudness
measurement.
Stop/Pause:
This control allows the user to terminate or pause the duration in which loudness values
are being used to calculate the
Integrated Loudness
measurement. Each time this button is activated,
a new
Integrated Loudness
value will be produced.
5.2.14.4. IntelliGain
®
Traps [+IG2]
The IntelliGain
®
audio loudness processing module can provide confidence monitoring with SNMP trap
alarm notification. These alarms can be enabled and disabled on an individual audio program basis
using the IntelliGain
Traps tab.
The IntelliGain Traps tab contains the IntelliGain
®
program trap enables, as well as corresponding trap
status for each IntelliGain
®
audio program. Figure 5-24 illustrates the layout of these controls in the
VistaLINK® PRO configuration view.
To enable or disable an SNMP alarm notification, either check or un-check the defined control.
The IntelliGain
®
audio loudness processing module also provides trap status information on the
IntelliGain traps tab. If a trap is sent by the IntelliGain
®
system, the trap status box will change state
indicating the current value for that trap. For example, if the trap status box is the colour green, then
the trap has not been sent, and the trap is not in the alarm state. However, if the status box is the colour
red, then the fault is in a current state of alarm. Once corrected, the status box will turn back to the
colour green.