![evertz 7847FSEDA Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/evertz/7847fseda-series/7847fseda-series_user-manual_2445249017.webp)
7847FSEDA Series
Frame Synchronizer and Distribution Amplifier
Revision 0.1
Page - 7
2.2.
ETHERNET CONNECTIONS
All 7847 series modules are designed to use either 10Base-T (10 Mbps) or 100Base-TX (100 Mbps)
also known as
Fast Ethernet
, twisted pair Ethernet cabling systems. When connecting for 10Base-T
systems, category 3, 4, or 5 UTP cable as well as EIA/TIA – 568-100
Ω
STP cable may be used.
When connecting for 100Base-TX systems, category 5 UTP cable is required. To establish the
network connection, plug one end of a
straight through
cable into the RJ-45 receptacle of the
7847FSEDA module and the other end into a port of the supporting hub. If you are connecting the
7847FSEDA series module directly to an Ethernet port on a computer, you will have to use a
crossover
cable.
Straight-through RJ-45 cables can be purchased or can be constructed using the pin out information in
Table 2-1 for the current RJ-45 standards (AT&T 258A or EIA/TIA 258B colour coding shown). Also,
refer to the notes following the table for additional wiring guide information.
Pin
1
Pin #
Signal
EIA/TIA 568A
AT&T 258A or
EIA/TIA 568B
10BaseT
or 100BaseT
1
Tr White/Green
White/Orange
X
2
Transmit –
Green/White or White
Orange/White or
Orange
X
3
R
White/Orange
White/Green
X
4
N/A
Blue/White or Blue
Blue/White or Blue
Not used
(required)
5
N/A
White/Blue
White/Blue
Not used
(required)
6
Receive –
Orange/White or
Orange
Green/White or Green
X
7
N/A
White/Brown
White/Brown
Not used
(required)
8
N/A
Brown/White or Brown
Brown/White or Brown
Not used
(required)
Table 2-1: Colour Code Wiring for the Current RJ45 Standards
Note the following cabling information for this wiring guide:
•
Only two pairs of wires are used in the 8-pin RJ 45 connector to carry Ethernet signals.
•
Even though pins 4, 5, 7 and 8 are not used, it is mandatory that they be present in the cable.
•
10BaseT and 100BaseT use the same pins; a crossover cable made for one will work with the
other.
•
Pairs may be solid colours and not have a stripe.
•
Category 5 cables must use Category 5 rated connectors.
The maximum cable run between the 7847FSEDA series modules and the supporting hub is 300 ft (90
m).
Содержание 7847FSEDA Series