![evertz 7847FSEDA Series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/evertz/7847fseda-series/7847fseda-series_user-manual_2445249060.webp)
7847FSEDA Series
Frame Synchronizer and Distribution Amplifier
Page - 50
Revision 0.1
Program Configuration Source:
This control defines how the input audio channels are grouped
together into programs for the IntelliGain
®
audio loudness processing. Up to eight channels can be
grouped together in individual programs, where each program contains its own metadata. IntelliGain
®
uses this parameter to configure multiple internal settings.
NOTE:
It is important to follow the program to channel mapping guidelines. For
example, Program Configuration Source
2 + 2 + 2 + 2
defines audio program 1 mapped
to input channels 1 & 2, audio program 2 mapped to input channels 7 & 8, audio
program 3 mapped to input channels 3 & 4 and audio program 4 mapped to input
channels 5 & 6. Program Configuration Source
2 + 2 + 2 + 2 (p1, p3, p4, p2)
has the
audio program mapped sequentially.