![evertz 7847FSEDA Series Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/evertz/7847fseda-series/7847fseda-series_user-manual_2445249037.webp)
7847FSEDA Series
Frame Synchronizer and Distribution Amplifier
Revision 0.1
Page - 27
Video Frozen:
This trap will trigger when a set of consecutive input video frames of length greater
than
Video Frozen Duration
all containing video activity (
motion
) below the video noise level. This
trap will
clear
when a set of consecutive input video frames of length greater than
Video Frozen
Timeout
all containing video activity (motion) above the picture noise level.
Black Level Error:
This trap will trigger when a set of consecutive input video frames of length
greater than
Black/White Level Error Duration
all containing more pixels below the
Black Error Level
than the threshold specified by the
Error Quantity
control. This trap will
clear
when a set of
consecutive input video frames of length greater than
Black/White Level Error Timeout
all containing
less pixels below the
Black Error Level
than the threshold specified by the
Error Quantity
control.
White Level Error:
This trap will trigger when a set of consecutive input video frames of length
greater than
Black/White Level Error Duration
all containing more pixels above the
White Error Level
than the threshold specified by the
Error Quantity
control. This trap will
clear
when a set of
consecutive input video frames of length greater than
Black/White Level Error Timeout
all containing
less pixels above the
White Error Level
than the threshold specified by the
Error Quantity
control.
Black Level Warning:
This trap will trigger when a set of consecutive input video frames of length
greater than
Black/White Level Warning Duration
all containing less pixels below the
Black Warning
Level
than the threshold specified by the
Error Quantity
control. This trap will
clear
when a set of
consecutive input video frames of length greater than
Black/White Level Warning Timeout
all
containing more pixels below the
Black Warning Level
than the threshold specified by the
Error
Quantity
control.
White Level Warning:
This trap will trigger when a set of consecutive input video frames of length
greater than
Black/White Level Warning Duration
all containing less pixels above the
White Warning
Level
than the threshold specified by the
Error Quantity
control. This trap will
clear
when a set of
consecutive input video frames of length greater than
Black/White Level Warning Timeout
all
containing more pixels above the
White Warning Level
than the threshold specified by the
Error
Quantity
control.