The firmware has 9 default maps, each of which
corresponds to a precise configuration.
The parameters of the active configuration can be changed
using the keypad or the EVJKEY key only if the controller is
in the OFF position.
The password must be entered to access the following
menus.
–
Configuration
:
PW “
19
”
only the “
type of application
” machine configuration
parameter will be visible and can be changed
The default parameters of the selected configuration
will always be loaded using this operation and the
present parameters will be overwritten
–
Service
:
PW “
-19
”
All the parameters, except the machine configuration
parameter, will be visible and can be changed
PW “
-20
”
all the parameters will be visible but cannot be changed
–
Restore
parameters
:
PW “
149
”
the default parameters of the active application will be
restored
N.B.: when the operation is complete, the controller will
automatically return to the OFF position
Changes using the keypad
If the REFRESH key
is held down for 3
seconds on the
“OFF screen”,
access will be
granted to the
“configuration
screen”
Configuration
screen Press the
“UP” and “DOWN”
keys to select the
menu, then the
“SET” key to
confirm
Password
Press the “UP” and “DOWN”
keys
to set the
password,
then the “SET”
key to confirm
and
access the menu
Making changes using the EVJKEY
Making changes using the EVJKEY
Making changes using the EVJKEY
Making changes using the EVJKEY
All the map of the parameters, including machine configuration, can be uploaded and downloaded using the EVJKEY key.
When downloading from the key to the controller, the parameters saved in the controller are the ones on the key and not
the default parameters.
OFF
CONFIGURATION
SERVICE
LANGUAGE
INTERNAL VALUES
RESTORE PARAMETERS
SET
-19
SET