EVJ 700
EVJ 700
EVJ 700
EVJ 700 ----
Application Manual:
144EVJ700E204
EVCO | 29.01.2021
| 45
Code
Code
Code
Code
Description
Description
Description
Description
Min
Min
Min
Min
Max
Max
Max
Max
Unit
Unit
Unit
Unit
E
le
c
tr
ic
h
o
t
p
la
te
s
E
le
c
tr
ic
h
o
t
p
la
te
s
E
le
c
tr
ic
h
o
t
p
la
te
s
E
le
c
tr
ic
h
o
t
p
la
te
s
B
a
in
B
a
in
B
a
in
B
a
in
----m
a
r
ie
m
a
r
ie
m
a
r
ie
m
a
r
ie
T
il
ti
n
g
p
a
n
s
T
il
ti
n
g
p
a
n
s
T
il
ti
n
g
p
a
n
s
T
il
ti
n
g
p
a
n
s
C
a
s
t
ir
o
n
g
r
il
ls
C
a
s
t
ir
o
n
g
r
il
ls
C
a
s
t
ir
o
n
g
r
il
ls
C
a
s
t
ir
o
n
g
r
il
ls
F
r
y
e
r
s
F
r
y
e
r
s
F
r
y
e
r
s
F
r
y
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
B
o
il
in
g
B
o
il
in
g
B
o
il
in
g
B
o
il
in
g
p
a
n
s
p
a
n
s
p
a
n
s
p
a
n
s
F
r
y
F
r
y
F
r
y
F
r
y
----
to
p
s
to
p
s
to
p
s
to
p
s
O
v
e
n
s
O
v
e
n
s
O
v
e
n
s
O
v
e
n
s
r20
r20
r20
r20
Time power regulator 1 is off
(if r20 = 0 and r19 ≠ 0, power regulator 1 is
always on)
0
240
Sec
10
NA
45
45
NA
45
NA
45
NA
r21
r21
r21
r21
Time power regulator 2 is on
1
240
Sec
4
NA
4
4
NA
4
NA
4
NA
r22
r22
r22
r22
Time power regulator 2 is off
(if r22 = 0 and r21 ≠ 0, power regulator 2 is
always on)
0
240
Sec
10
NA
38
38
NA
38
NA
38
NA
r23
r23
r23
r23
Time power regulator 3 is on
1
240
Sec
6
NA
5
5
NA
5
NA
5
NA
r24
r24
r24
r24
Time power regulator 3 is off
(if r24 = 0 and r23 ≠ 0, power regulator 3 is
always on)
0
240
Sec
10
NA
32
32
NA
32
NA
32
NA
r25
r25
r25
r25
Time power regulator 4 is on
1
240
Sec
8
NA
7
7
NA
7
NA
7
NA
r26
r26
r26
r26
Time power regulator 4 is off
(if r26 = 0 and r25 ≠ 0, power regulator 4 is
always on)
0
240
Sec
10
NA
29
29
NA
29
NA
29
NA
r27
r27
r27
r27
Time power regulator 5 is on
1
240
Sec
10
NA
9
9
NA
9
NA
9
NA
r28
r28
r28
r28
Time power regulator 5 is off
(if r28 = 0 and r27 ≠ 0, power regulator 5 is
always on)
0
240
Sec
10
NA
30
30
NA
30
NA
30
NA
r29
r29
r29
r29
Time power regulator 6 is on
1
240
Sec
12
NA
13
13
NA
13
NA
13
NA
r30
r30
r30
r30
Time power regulator 6 is off
(if r30 = 0 and r29 ≠ 0, power regulator 6 is
always on)
0
240
Sec
10
NA
32
32
NA
32
NA
32
NA
r31
r31
r31
r31
Time power regulator 7 is on
1
240
Sec
NA
NA
21
21
NA
21
NA
21
NA
r32
r32
r32
r32
Time power regulator 7 is off
(if r32 = 0 and r31 ≠ 0, power regulator 7 is
always on)
0
240
Sec
NA
NA
37
37
NA
37
NA
37
NA
r33
r33
r33
r33
Time power regulator 8 is on
1
240
Sec
NA
NA
45
45
NA
45
NA
45
NA
r34
r34
r34
r34
Time power regulator 8 is off
(if r34 = 0 and r33 ≠ 0, power regulator 8 is
always on)
0
240
Sec
NA
NA
60
60
NA
60
NA
60
NA
r35
r35
r35
r35
Time power regulator 9 is on
1
240
Sec
NA
NA
1
1
NA
1
NA
1
NA
r36
r36
r36
r36
Time power regulator 9 is off
(if r36 = 0 and r35 ≠ 0, power regulator 9 is
always on)
0
240
Sec
NA
NA
0
0
NA
0
NA
0
NA
r37
r37
r37
r37
Technical room fan setpoint (only for models
with J/K thermocouples)
0
99
°C\°F
50
50
50
50
50
50
50
50
50
r38
r38
r38
r38
Proportional band 0
= on-off control
0
99
°C\°F
NA
0
0
NA
0
NA
0
NA
0
r39
r39
r39
r39
Integral action time
0 = only proportional action
0
999
Sec
NA
0
0
NA
0
NA
0
NA
0
r40
r40
r40
r40
Delay between 2 heater switch-ons
60
240
Sec
NA 180 180 NA 180
NA 180
NA 180
r41
r41
r41
r41
Minimum time heater on/off
10
240
Sec
NA
10
10
NA
10
NA
10
NA
10
r42
r42
r42
r42
∆T setpoint
r43
r44
°C\°F
NA
NA
NA
NA
NA
NA
NA
NA
5
r43
r43
r43
r43
Minimum ∆T setpoint
0
r44
°C\°F
NA
NA
NA
NA
NA
NA
NA
NA
0
r44
r44
r44
r44
Maximum ∆T setpoint
r43
150
°C\°F
NA
NA
NA
NA
NA
NA
NA
NA
30
Digital inputs
Digital inputs
Digital inputs
Digital inputs
i2
i2
i2
i2
Door open alarm delay
-1 = Disabled
-1
120
Min
NA
NA
-1
NA
NA
NA
NA
NA