Bain
Bain
Bain
Bain----marie
marie
marie
marie
Inputs available
–
Regulation probe
–
Push encoder
–
Level sensor (digital input)
Outputs available
–
Heater
–
Solenoid valve to load water
–
Solenoid valve to discharge water
–
ON-OFF
–
Technical room fans
Solenoid valves can never be activated at the same time
Information displayed
The display shows the cooking time and the temperature of the tank. The temperature can refer to the reading or the
setpoint, depending on how parameter “
e4
” is set.
Switch-on screen
Regulation screen
Available functions
Device ON/OFF
When the display is switched on, the following values are uploaded:
Temperature: 0
Timer time 00:00 hh:mm
Selection of tank temperature
Selection range [0 (r1) <-> 90°C (r2)]
Selection of cooking time
Selection range [00:00 <-> 59:59 mm:ss]
Water filling
activation/deactivation of the solenoid valve to fill the tank.
This key works in a similar way to a switch, the solenoid valve is activated when it is pressed. When it is pressed
again, the solenoid valve is deactivated (“
toggle
” switch).
To activate it, the key must be held down for 3 seconds, whereas deactivation is immediate.
If the level sensor is fitted, the water stops loading as soon as the maximum level
is detected by the sensor.
If the solenoid valve is active, the icon flashes
If the solenoid valve is deactivated, the icon stays on