![Evco EVJ 700 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/evco/evj-700/evj-700_applications-manual_2441834047.webp)
EVJ 700
EVJ 700
EVJ 700
EVJ 700 ----
Application Manual:
144EVJ700E204
EVCO | 29.01.2021
| 47
Code
Code
Code
Code
Description
Description
Description
Description
Min
Min
Min
Min
Max
Max
Max
Max
Unit
Unit
Unit
Unit
E
le
c
tr
ic
h
o
t
p
la
te
s
E
le
c
tr
ic
h
o
t
p
la
te
s
E
le
c
tr
ic
h
o
t
p
la
te
s
E
le
c
tr
ic
h
o
t
p
la
te
s
B
a
in
B
a
in
B
a
in
B
a
in
----m
a
r
ie
m
a
r
ie
m
a
r
ie
m
a
r
ie
T
il
ti
n
g
p
a
n
s
T
il
ti
n
g
p
a
n
s
T
il
ti
n
g
p
a
n
s
T
il
ti
n
g
p
a
n
s
C
a
s
t
ir
o
n
g
r
il
ls
C
a
s
t
ir
o
n
g
r
il
ls
C
a
s
t
ir
o
n
g
r
il
ls
C
a
s
t
ir
o
n
g
r
il
ls
F
r
y
e
r
s
F
r
y
e
r
s
F
r
y
e
r
s
F
r
y
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
P
a
s
ta
c
o
o
k
e
r
s
B
o
il
in
g
B
o
il
in
g
B
o
il
in
g
B
o
il
in
g
p
a
n
s
p
a
n
s
p
a
n
s
p
a
n
s
F
r
y
F
r
y
F
r
y
F
r
y
----
to
p
s
to
p
s
to
p
s
to
p
s
O
v
e
n
s
O
v
e
n
s
O
v
e
n
s
O
v
e
n
s
Digital outputs
Digital outputs
Digital outputs
Digital outputs
uc1
uc1
uc1
uc1
K1 relay configuration
0 = Not used
1 = Heater
2 = Bottom heater
3 = Top heater
4 = Water solenoid valve
5 = Hot water solenoid valve
6 = Cold water solenoid valve
7 = Slow load solenoid valve
8 = Rapid load solenoid valve
9 = Alarm
10 = Discharge solenoid valve
11 = Technical room fans
12 = Motor basket 1
13 = Motor basket 2
14 = ON-OFF
15 = AUX
0
15
---
1
1
1
1
1
1
1
1
2
uc2
uc2
uc2
uc2
K2 relay configuration: as “uc1”
0
15
---
0
4
4
5
15
0
12
7
3
uc4
uc4
uc4
uc4
K4 relay configuration: as “uc1”
0
15
---
11
10
11
6
11
11
11
8
11
uc5
uc5
uc5
uc5
K5 relay configuration: as “uc1”
0
15
---
14
14
14
14
14
14
14
14
14
uc6
uc6
uc6
uc6
K6 relay configuration: as “uc1”
0
15
---
0
11
0
11
0
0
13
11
0
PSr
PSr
PSr
PSr
Enable silencing alarm output
0 = No
1 = Yes
0
1
---
1
1
1
1
1
1
1
1
1
Pbu
Pbu
Pbu
Pbu
Buzzer configuration
0 = Disabled 1
= Only alarms
2 = keypad
0
2
---
2
2
2
2
2
2
2
2
2
SEn
SEn
SEn
SEn
Capacitive keypad threshold
60
120
---
70
70
70
70
70
70
70
70
70
Configurations
Configurations
Configurations
Configurations
e1
e1
e1
e1
Type of application
0 = None
1 = Electric hot plates
2 = Bain-marie
3 = Tilting pans
4 = Boiling pans
5 = Fry-tops
6 = Cast iron grills
7 = Fryers
8 = Pasta cookers
9 = Ovens
0
9
---
1
2
3
4
5
6
7
8
9
e2
e2
e2
e2
Time of buzzer activation from end of timer and
from reached setpoint
-1 = Until silencing
0 = Disabled
-1
120
Sec
30
30
30
30
30
30
30
30
30
e3
e3
e3
e3
Value displayed in stand-by
0 = Label "OFF"
1 = Key on/off icon
0
1
---
0
0
0
0
0
0
0
0
0
e4
e4
e4
e4
Value displayed when on
0 = Reading regulation and needle probes
1 = Setpoint regulation and needle probes
0
1
---
NA
0
0
NA
0
NA
0
NA
0
e5
e5
e5
e5
Timer displayed at end of count
0 = 00:00
1 = Last set value
0
1
1
1
1
1
1
1
1
1
1