EVJ 700
EVJ 700
EVJ 700
EVJ 700 ----
Application Manual:
144EVJ700E204
EVCO | 29.01.2021
| 38
Pasta cookers
Pasta cookers
Pasta cookers
Pasta cookers
Inputs available
–
Push encoder
Outputs available
–
Heater
–
Solenoid valve rapid tank filling
–
Solenoid valve slow tank filling
–
ON-OFF
–
Technical room fans
N.B.: solenoid valves can never be activated at the same time
Information displayed
The display shows the value of the power and the cooking time of selected basket. The application is able to manage up to
6 timers, from T1 to T6, which are independent of each other, one for each configured basket.
When the machine is switched on, only the time T1 of the first basket will be displayed by default, while the timers
T2 to T6 will only be displayed when selected.
Once the timer has elapsed, the display will still show the value “0” until the controller is switched off.
After switch-on
During regulation with more timers selected
Available functions
Device ON/OFF
When the display is switched on, the following values are uploaded:
Power: 0
Timer time T1: 00:00
Power regulation:
Selection interval: [0<->9]
Selection of active basket
Choice of basket which the timer applies to: touch the key until the basket to be activated is selected and
hold it down for 3 seconds
Selection interval: [0 <-> 6]
Selection of cooking time (referring to the selected basket T1-> T6)
Selection range: [00:00<->59:59 mm:ss]