EVJ 700
EVJ 700
EVJ 700
EVJ 700 ----
Application Manual:
144EVJ700E204
EVCO | 29.01.2021
| 22
Setting the setpoint
Only the settable values are displayed, according to the type of cooking selected.
Timed cooking
∆T cooking
Needle cooking
The selection ranges/intervals for each value are the following:
Temperature of regulation probe [0 <-> 300°C]
Temperature of
∆T [0 <-> 150°C]
Time [00:00 <-> 24:00 hh:mm]
Temperature of needle probe [0 (r4) <-> 99 (r5) °C]
Selection of heaters:
Top heaters on
Bottom heaters on
Top + bottom heaters on
Refresh
This reloads the last time value set on the selected timer