Cold water filling
activation/deactivation of the solenoid valve to fill the tank.
This key works in a similar way to a switch, the solenoid valve is activated after it is pressed. When it is pressed again, the
solenoid valve is deactivated (“toggle” switch).
To activate it, the key must be held down for 3 seconds, whereas deactivation is immediate.
When the function is active, the icon flashes.
When the function is deactivated, the icon stays on.
Refresh
This reloads the last time value set on the selected timer
Operation
–
All the functions listed above can be selected using the function keys or the push encoder, as described in the general
introduction.
–
During setting, the value to change will flash.
The hours/minutes or minutes/seconds on the timer are modified separately.
If confirmation is not given within 5 seconds, it will automatically validate the displayed value.
–
The controller begins regulation when the value of the energy regulator is anything other than “0”, based on
the regulation value set by the relative parameters:
–
Regulator 1: 3” ON (r19)/45” OFF (r20)
–
Regulator 2: 4” ON (r21)/38” OFF (r22)
–
Regulator 3: 5” ON (r23)/32” OFF (r24)
–
Regulator 4: 7” ON (r25)/29” OFF (r26)
–
Regulator 5: 9” ON (r27)/30” OFF (r28)
–
Regulator 6: 13” ON (r29)/32” OFF (r30)
–
Regulator 7: 21” ON (r31)/37” OFF (r32)
–
Regulator 8: 45” ON (r33)/60” OFF (r34)
–
Regulator 9: always ON (r35/r36)
–
Heating is interrupted when the power regulator is set with a value of “0” or when the controller is switched OFF.
–
When countdown ends (time at 00:00), the buzzer will sound until the button on the push encoder (or one of the 6
function keys) is pressed or or until the timeout interval set by the relative parameter (e2) elapses, with a cycle of 0.5
“ON/0.5” OFF. This does not affect the regulation, the device will continue normal regulation.
Management of technical room fan output and ON-OFF output
–
If one of the available outputs is configured as “technical room fans” (value set to 11), the fans are always on
(except for models with J/K thermocouples, where they are activated when the threshold set by parameter r37
is exceeded).
–
–
If one of the available outputs is configured as “ON-OFF” (value set to 14), the relay will operate as follows:
–
OFF when the device is on stand-by mode
–
ON under all other conditions